VGTU talpykla > Aplinkos inžinerijos fakultetas / Faculty of Environmental Engineering > Konferencijų straipsniai >

Lietuvių   English
Please use this identifier to cite or link to this item: http://dspace.vgtu.lt/handle/1/638

Title: Traceability, Stability and Use of the Kyviskes Calibration Baseline – The First 10 Years
Authors: Būga, Arūnas
Jokela, Jorma
Putrimas, Raimundas
Keywords: geodetic baseline
traceability
calibration
EDM
Issue Date: 2008
Publisher: Vilniaus Gedimino technikos universitetas
Citation: Būga, A.; Jokela, J.; Putrimas, R. 2008. Traceability, stability and use of the Kyviskes calibration baseline – the first 10 years, in The 7th International Conference “Environmental engineering”: Selected papers, Vol. 3. Ed. by D. Čygas, K. D. Froehner, May 22–23, 2008 Vilnius, Lithuania. Vilnius: Technika, 1274–1280.
Abstract: The Kyviškės Calibration Baseline was established by the Institute of Geodesy of the Vilnius Gediminas Technical University (VGTU) in 1996 for calibration of electronic distance measurement (EDM) instruments. The length of the 6-pillar baseline is 1 320 m, and a 7th pillar, established in 2000, extends it to a triangle-shaped test field. The Finnish Geodetic Institute, together with the Institute of Geodesy of VGTU, is measuring the baseline in 5– 6 years cycles with high precision instruments. Calibration results (lengths and uncertainties) of the three first measurements in 1997, 2001 and 2007 are presented. As an essential part of a metrological work, the traceability chain and measurement methods are described as well. The traceability chain from the definition of the metre to baseline lengths consists of several stages: absolute and relative measurements of quartz gauges, standard baseline measurements using white-light interferometry, projection measurements enabling calibration of transfer standards, and finally, calibration of the calibration baseline itself. After all this, 0.2 mm to 1.2 mm total uncertainties have been repeatedly obtained for the lengths of the pillar intervals at Kyviškės. Furthermore, the three results are compatible within the uncertainty limits, showing the baseline and test field very stable. In addition to testing and calibration of EDM instruments, Kyviškės is suitable for testing of total stations and GNSS measurement equipment.
URI: http://dspace1.vgtu.lt/handle/1/638
ISBN: 978-9955-28-265-5
Appears in Collections:Konferencijų straipsniai

Files in This Item:

File Description SizeFormat
buga_et_al_traceability.pdf1.07 MBAdobe PDFView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback